Leave Your Message
UV Measurement Equipment

UV Measurement Equipment

Item Probe type Spectral response range Power range Test aperture Application
LS125 UVC-X0 230-280nm 0 - 200000 μW/cm² Φ10mm 254nm UV sterilization mercury lamp
UVC-X2 210-250nm 0 - 200000 μW/cm² Φ10mm 222nm UV germicidal lamps
UVCWP-X1 230-280nm 0 - 200000 μW/cm² Φ10mm 254nm UV sterilization mercury lamp, waterproof
UVCLED-X0 240-320nm 0 - 200000 μW/cm² Φ10mm 260nm-285nm UV LED germicidal lamp
UVB-X0 280-315nm 0 - 200000 μW/cm² Φ10mm General UVB intensity and energy measurement
UVA-X0 315-400nm 0 - 2000 mW/cm² Φ10mm High pressure mercury lamp in UV curing industry
UVA-X1 315-400nm 0 - 200000 μW/cm² Φ10mm General UVA intensity and energy measurement
UVA-X2 315-365nm 0 - 200000 μW/cm² Φ10mm 340nm UVA aging lamps
UVALED-X0 340-420nm 0 - 20000 mW/cm² Φ10mm Area light source of UV LED in UV curing industry
UVALED-X1 340-420nm 0 - 20000 mW/cm² Φ1mm Point light source of UV LED in UV curing industry
UVALED-X3 340-420nm 0 - 200000 μW/cm² Φ10mm General UVA+UVV LED, low power measuring range
BL-X0 410-490nm 0 - 2000 mW/cm² Φ10mm 450nm blue light LED sources
LS125-1
LS125-2
Item Parameter Value
LS128 Application Light intensity, energy and temperature measurement of UV LED light sources
Spectral range 340nm - 420nm, calibrated at 395nm UV LED light sources
Irradiance measuring range 0 - 40000 mW/cm²
Irradiance resolution 1 mW/cm²
Energy measuring range 0 - 999999 mJ/cm²
Energy measuring accuracy ± 10% , ± 5% (typical)
Temperature measuring range -55°C -125°C
Sampling speed 2048 times/second
Irradiance data storage interval 32 times/second
Temperature data storage interval 2 times/second
Recording period 32 min
Power supply 2 AAA alkaline dry batteries
Display 240*160 Dot matrix LCD
Test Hole Diameter Φ10mm
Dimension Diameter 120mm * Thickness 13mm
Weight 327g
LS128-1
LS18-2
Item Parameter Value
LS138 Spectral Range UVC: 230nm-280nm λp = 254nm;
UVB: 280nm-315nm λp = 310nm;
UVA: 315nm-400nm λp = 365nm;
UVV: 395nm-445nm λp = 420nm;
Power Measuring Range 0 - 2000 mW/cm²
Power Resolution 0.01 mW/cm²
Energy Measuring Range 0 - 999999mJ/cm²
Measuring Accuracy(H is the Standard Value) H<5mW/cm²: ±0.5mW/cm²
H>=5mW/cm²: ±10%H, ±5% (typical)
Temperature Measuring Range -55°C - +125°C
Sampling Speed 2048 times/second
Power Data Storage Interval 32 times/second
Temperature Data Storage Interval 2 times/second
Recording Period 32 min
Power Supply 2 AAA alkaline dry batteries
Display Dot matrix LCD
Dimension Diameter 120mm * thickness 13mm
Weight 327g
LS138-1
LS138-2